Waycon Positionsmesstechnik
 
 
 

Magnetostrictive

An elastic deformability of a wave guide is generated by overlayed magnetical fields. The transit time of the mechanical pulse is proportional to the distance between signal conditioning unit and permanent magnet. It is a contactless and absolute measuring principle.

Product MAB MAZ MSB
Range 100-4000mm 100-4000mm 100-4000mm
Resolution 2µm, 5µm, 10µm 2µm, 5µm, 10µm 10µm
Measured value position/speed position/speed position
Accuracy 0,02% 0,02% 0,02%
Speed < 10 m/s < 10 m/s < 10 m/s
Analog output 0-10 V, ±10 V, ±5 V, 4-20 mA, 0-20 mA 0-10 V, 0-20 mA, 4-20 mA, (invertiert) 0,1 -10,1 V, 0,1 -5,1 V, 4-20 mA
Digital output Start/Stop, PWM, SSI, Profibus, CANopen SSI, Profibus, CANopen start/stop
Voltage rating 24 V±20% 24 V±20% 18 – 30 V
Power input 100 mA 100 mA 40 mA
Protection class IP67 IP67 IP67
Operating temperatur -30°C..+75°C -30°C..+75°C -30°C..+90°C
Operating pressure until 350 Bar until 350 Bar
Magnet silding cursor or floating magnet swimmer, open ring, closed ring open ring, closed ring
Data sheet  
CAD data + + +



Applications

Specials

 

pneumatic and hydraulic cylinders

automotive industry

plastics industry

packing industry

wood industry

presses

conveying

textile industry

 

ranges from 100 mm...4000 mm

resolution <= 0.1 mV oder <= 0.,2 µA

linearity ± 0.02 % MB

protection up to IP 67

temperatur 40...+ 70 °C

displacement speed 10 m/s

contactless measurement

variable mounting


Magnetostrictive Transducers Series MAB

The magnetostrictive transducers MAB with SSI interface have been renewed, increasing performance to satisfy market demands. The electronics has been completely redesigned to improve the linearity and communication of all models.

The magnetostrictive transducers, SSI interface models have an extremely wide range of application. This protocol, with its immunity to noise and high adaptability to the communication interface, provides very precise measurement reads. Among the principal innovations is the new “internal linearization” option, which provides linearity up to 4 times higher than the standard version by performing linearity compensation in the electronics.

The entire SSI series has been given new electronics compatible with EMC standards and is more resistant to power surges. The reduction in overall noise improves transducer communication. In addition, the communication structure has been aligned in all versions (with and without the oversampling algorithm), making the entire series more compatible with SSI sensors made by other companies. With regard to technical specifications, maximum working temperature has been raised to 90°C and current input has been halved, dropping to 50 mA, the lowest level on the market for this product!

 
Munich:
 
Headquarter:
Mehlbeerenstr.4
82024 Taufkirchen
Fon: +49 (0) 89 / 67 97 13 - 0
Fax: +49 (0) 89 / 67 97 13 - 250
Cologne:
Auf der Pehle 1
50321 Brühl
Fon: +49 (0) 2232 / 56 79 44
Fax: +49 (0) 2232 / 56 79 45
Waycon im social web
Waycon bei FacebookWaycon bei TwitterWaycon bei YoutubeWaycon bei WordpressblogWaycon bei BloggerWaycon bei Flickr
Social Bookmarks
Diese Seite bei Mr. Wong merkenDiese Seite bei del.icio.us merkenDiese Seite bei Oneview merkenDiese Seite bei Webnews merkenDiese Seite bei Linkarena merkenDiese Seite bei Technorati merken

 

 
Print         Sitemap / Terms & Conditions
top