DRAW WIRE

This is a page from the old website.

 

new site

 

 

Click into the left menu bar in order to get to the new homepage.


 

 

Draw Wire


Specials


Applications

Draw wire sensors are suitable for measuring linear and non-linear motions. The compact style allows flexible and easy installation. Due to the small size, precise measurement is possible even in difficult applications.

easy installation

machine building industry

highly dynamic applications

medical applications

robust housing

store and convey technics

nylon jacketed stainless steel rope

loading platforms, cranes

variable outputs

automotive industry

non linear motions

robot positioning

customised versions

steel manufactering machinery

up to IP 65

flood gates

 

 


 

 

 

 

 

 

SX Series mit pricelist Industrial Draw Wire - Series SX

SX Series

range

50 / 125 / 150 / 250 / 375 / 500 / 625 / 1250 mm
2 / 2,5 / 3 / 4 / 5 / 6 / 8 / 10 / 15 / 20 /  25 /  30 m
35 / 40 m

output

0...10V (galvanic isolated) 
4...20 mA 
potentiometer 1 k Ohm 
incremental (pulse/mm) 
parallel / SSI / BUS

linearity

±0,10% analogue 
±0,05% digital

resolution

max. 27 pulse per mm 
or up to 24 Bit digital

acceleration

max. 170 m/s²

speed

max. 10 m/s

pull out force

dep. on type

protection

IP 65

temperature

-20...+70°C

supply

5 / 11...30 VDC

housing

aluminum titan anodised

 


 

 

 

 

 

 

Series HX

range

2,5 / 3 / 5 / 6 / 7,5 / 8,8 / 10 / 12 / 15 / 20 / 25 / 30 / 40 / 45 / 50 m

output

0...10V, 4...20 mA 
potentiometer 1 k Ohm 
incremental (Pulse/mm) 
velocity-position output

linearity

±0,15% analogue 
±0,03% digital

resolution

3 up to 20 pulses per mm

speed

max. 10 m/s

pull out force

5,3...10 N

protection

IP 65 / IP68

temperature

-25...+80°C

supply

11...35 VDC

housing

aluminum, polyurethane-housings

 


 

 

 

 

 

 

Miniature Draw Wire - Series LX

range

50 / 70 / 96 / 120 / 250 / 380 / 500 / 625 / 750 / 1000 / 1250 mm

protection

no protection

weight

85 g

housing

thermoplastic case 
(dimensions: 44,5 x 45,7 x 55,1 mm)!



LX-PA

output

potentiometer 1 k

resolution

nearly infinite

repeatability

0,03%

linearity

0,25%

temperature

-15...+60°C

supply

max. 25 V



LX-EP

output

A,B-signals, NPN

resolution

2 / 4 pulses per mm

repeatability

0,015%

linearity

0,10%

temperature

-25...+60°C

supply

5 VDC